Construction of A new entrance extension and office at the main South Building

Foundations

Piled foundations with a reinforced concrete ring beam / ground floor structure were installed.

Steel Frame

A structural steel framework was erected to provide the main support for the new construction.

External Walls

Timber-framed external walls were insulated and cladded with larch.

Roof with Felt Padding

A timber-framed flat roof was insulated and covered with a 3-layer high-performance felt.

Aluminium Glazing

Double-glazed aluminium entrance doors and windows were installed.

Internal Layout

Internal partitions, including a new reception counter and glazed screen were constructed.